MEMoRIAL-M1.10 | Deep learning for interventional C-arm CT
Projektleiter:
Projektbearbeiter:
M.Sc. Philipp Ernst
Finanzierung:
Forschergruppen:
The CT reconstruction task, addressing the determination of an underlying 3D volume from a series of projections, corresponds to the solution of a huge system of linear equations. Modern deep-learning methods provide an effective tool to perform such tasks.
To date, CT scans always acquire a complete set of x-ray projections of the examination object disregarding the fact, that it might be about one and the same patient being multiply and/or repeatedly screened.
Moreover, complete CT scans result in identically high doses of ionising radiation as well as long scan durations.
Prior knowledge e.g. including generalisable information on human anatomy or even the availability of individual data based on previous, patient-specific scans is presently not taken into account.
This holds particularly true for image-guided interventions such as inserting a needle into a tumour for the purpose of ablation. The associated exposures only differ with respect to the needle's position - an information being derivable also from a single projection within the scope of a suitable setting.
The aim of this sub-project is to study, whether CT reconstruction by means of deep learning methods allows for the imaging and detection of very small changes of the scene based on a number of relevant projections as minimal as possible.
If applicable, significantly reduced radiation doses linked to shorter scan times may result, enabling the real-time imaging during interventions.
To date, CT scans always acquire a complete set of x-ray projections of the examination object disregarding the fact, that it might be about one and the same patient being multiply and/or repeatedly screened.
Moreover, complete CT scans result in identically high doses of ionising radiation as well as long scan durations.
Prior knowledge e.g. including generalisable information on human anatomy or even the availability of individual data based on previous, patient-specific scans is presently not taken into account.
This holds particularly true for image-guided interventions such as inserting a needle into a tumour for the purpose of ablation. The associated exposures only differ with respect to the needle's position - an information being derivable also from a single projection within the scope of a suitable setting.
The aim of this sub-project is to study, whether CT reconstruction by means of deep learning methods allows for the imaging and detection of very small changes of the scene based on a number of relevant projections as minimal as possible.
If applicable, significantly reduced radiation doses linked to shorter scan times may result, enabling the real-time imaging during interventions.
Anmerkungen
Wiss. Co-Betreuende / Scientific Co-Supervisors: Robert Frysch (OVGU:FEIT/IMT, STIMULATE); Prof. Dr. Georg Rose (OVGU:FEIT/IMT, STIMULATE)
Kooperationen im Projekt
Publikationen
Die Daten werden geladen ...
Die Daten werden geladen ...
Die Daten werden geladen ...
Kontakt
Prof. Dr. Andreas Nürnberger
Otto-von-Guericke-Universität Magdeburg
Institut für Technische und Betriebliche Informationssysteme
Universitätsplatz 2
39116
Magdeburg
Tel.:+49 391 6758665
weitere Projekte
Die Daten werden geladen ...